Daihan Scientific MS-MP8 Instrukcja obsługi - Strona 12

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Sprzęt laboratoryjny Daihan Scientific MS-MP8. Daihan Scientific MS-MP8 15 stron. Digital multi-point magnetic stirrers

DAIHAN-Sci.com or ALL for LAB.com Shopping Mall
3. Product Usage

3.3 Usage Instructions

Please proceed as described in this manual when operating this product.
-
1. Power-On: Turn on the power switch, then the MS-MP4/8 get into RPM mode.
Mode Selection: MS-MP4/8 series have 3 different Modes including default Mode. You can
change the mode by push MODE switch ⑦. 3 Modes are; (1) Set Stirring Mode, (2) Set
Timer Mode and (3) Locking Mode. Default mode is the (1) Set Stirring Mode.
Power On
MODE
button
In <fig. 2>, ②Set Value and ③Measured Value have different meaning for each operation
mode. It is shown in the following <Table 1>.
<Table 1> the meaning of digit by mode
Setting Mode
Set Stirring Mode
Set Timer Mode
Locking Mode
2. Set Stirring (RPM) Mode
A. After you turn on the power and select the RPM mode, you can see the Set Value is
zero or non-zero on LCD panel.
i.
If the Set Value is non-zero, it means someone has saved a set-value previously.
You can use the saved value or you can modify the value by turning the jog-
shuttle. Simply by clicking jog-shuttle, the unit begins to operate with the set RPM.
DAIHAN Scientific, MS-MP4/8 Multipoint Magnetic Stirrer
Stirring Mode
Locking Mode
Set Value
Set(Saved) Speed
(RPM)
Set(Saved) Time
Current Speed
MODE
button
Timer Mode
MODE
button
Measured Value
Current Speed
(RPM)
Time remained
Time remained
Control target
Stirring Speed
(RPM)
Operation time
Display only
12 / 15