VI. AUTO POWER OFF
When the tester is idle for thirty minutes, with no function selector
or button operation, it will turn itself off automatically. To turn the
tester on again, the user has to turn the function selector to "OFF"
position, then the selected function.
VII. BATTERY CHANGING
When
appear on the LCD, the battery need to be replaced with
new ones. To replace the battery the user should turn the function
selector to OFF position. Then the user needs to open the battery
compartment cover with a screwdriver. Eight AA 1.5V batteries are
needed to replace the old ones. After all Batteries are changed,
put the cover back and fasten the screw.
VIII. FUSE CHANGING:
When connect the meter under Ohm rang to a source > 10V, the
protection fuse will break the circuit and new one will be needed
for replacement. To replace the fuse, user should prepare an F
0.5A 600V fuse. First, the user should turn the tester off and
remove the test leads then remove the Back Cover and Replace
the fuse.
10
amb 45