Draper Access FIT Series Instrukcja
Przeglądaj online lub pobierz pdf Instrukcja dla Ekran projekcyjny Draper Access FIT Series. Draper Access FIT Series 4 stron. Electric projection screen 220v
Również dla Draper Access FIT Series: Instrukcja instalacji i obsługi (8 strony)
Access Fit
Electric Projection Screen
CAUTION
Read instructions through completely before proceeding.
1
Follow instructions carefully. Installation contrary to instructions invalidates
2
warranty.
Screen should be accessible for complete removal should fabric become
3
damaged or should other service be required.
Screen should be installed level
4
must also be installed so that the top of the case is level
prevent the fabric from contacting the case housing.
Nothing should be fastened to screen dowel or viewing surface.
5
Operating
switch(es)
packed separately in screen carton.
6
Do not discard with packing material.
Screen operates on 110-120V, 60 hz. current.
7
Screen has been thoroughly inspected and tested at factory and
found to be operating properly prior to shipment.
These instructions are meant as a guide only. They do not imply any
responsibility on the part of the manufacturer for improper installation or
faulty workmanship at the jobsite.
Hanging Screen
When locating viewing surface
and checking clearance for screen
operation, remember surface is
centered in the length of the case.
Regardless of mounting method
used, the following points apply:
Mounting brackets are shipped
1
attached to the case. Engage
each bracket with top of housing
as shown below and tighten set
screws.
Screen should be positively and
2
securely supported so that vibration or even abusive pulling on viewing surface
will not weaken installation.
Please Note: A Hoisting Bracket is included on each end of the case to aid in
overhead installation of the Access Fit case.
Installer must insure that fasteners used are of adequate strength and suitable
3
for the mounting surface chosen. Supporting hardware
rods, etc.)
must be essentially vertical.
Entire bottom of case must be readily accessible after installation is complete.
4
Front, back and top of case must be straight— not forced to warp or bow.
5
If case is painted on location, removal of roller/fabric assembly is
6
recommended prior to painting. If not removed, slot on bottom of case should
be shielded to protect viewing surface from paint splatters/overspray.
Do not seal unit in ceiling until electrical connections have been made and
7
screen has been operated successfully.
Figure 2
7
ELECTRICAL
CUTOUT
7
/
8
ELECTRICAL
CUTOUT
Typical
Installation
1
With typical installation, brackets may be angled to meet installation requirements.
1
Suitable for use in environmental air space in accordance with Section
300-22(c) of the National Electrical Code, and Sections 2-128, 12-010(3) and
12-100 of the Canadian Electrical Code, Part 1, CSA C22.1.
(using a carpenter's
level). The case
(front-to-back)
Removing Shipping Brackets
DO NOT OPERATE SCREEN BEFORE
REMOVING THESE SHIPPING
BRACKETS FROM SCREEN CASE
Figure 1
1. Remove Fasteners
from Bracket Clamps
2. Run the screen
DOWN to expose
the Dowel Screws
3. Loosen screws
and remove the
4. Retighten dowel
shipping bracket.
endcap screws.
(chains, cables, 3/8"
"
/
8
"
Alternate
Installation
(additional set of
brackets required
but not included)
Electrical Connections
Screen operates on 110-120V, 60 hz., 1.1 amp current draw.
Duty Cycle: ON 28 seconds /OFF 4 minutes.
Junction box is located just above the bottom access panel at left end of
screen
(standard, right end may be
Remove the bottom access panel for access to the junction box cover.
Bottom Access Panel Removal instructions
screws that secure the cover to the junction box to expose the red, black, and
white pigtail leads and the green ground wire per wiring diagram on page 4.
to
If optional low voltage control is specified and factory installed, please refer to
wiring diagrams on page 4.
Screen is shipped with internal wiring complete and control
boxed. Wire to connect screen to
should be furnished by installer. Connections should be made in accordance
with attached wiring diagram, and wiring should comply with national and local
electrical codes.
All operating switches should be "off" before power is connected.
Bottom Access Panel Installation/Removal
Bottom access panel is secured to the screen housing by two screws
each
end), and is held in the closed position by engagement brackets with ball
detents that snap into case support brackets.
To remove the Access Panel:
Access Fit
case as seen
from below
Bottom Access Panel Door
Caution: Beware of pinch points at ends of closure
Remove screws from both ends of screen housing
1
Pull down on the access panel until the ball detents on the engagement
2
bracket have disengaged from the support bracket.
Repeat Step 2 for all brackets along the length of the screen housing.
3
Figure 4
Remove Screws
from both ends
of Screen Housing
The access panel will be free to pivot downward. It will remain attached to the
4
lower inside edge of the screen housing by several steel hinges.
Caution: For larger sizes Step 5 requires two people to perform safely.
Press up on access panel and pull toward the front of the screen housing to
5
disengage hinges and remove access panel.
To Remove/Install Support Brackets:
Figure 5
Access Fit Electric Projection Screen, call your dealer or Draper, Inc.
INSTRUCTIONS
INSTALLATION & OPERATION
specified).
below). Remove two
switch(es)
switch(es)
and
switch(es)
to power supply
Bottom flange of
Figure 3
Access housing
(Fig.
3).
Access
Panel Door
pivot on Hinges
A
P
CCESS
ANEL
S
B
UPPORT
RACKET
A
TTACHING BRACKETS
Insert pin in top
1
slot and push up
Rotate bracket
2
clockwise to lock
bracket in place
E
B
NGAGEMENT
RACKET
B
D
WITH
ALL
ETENT
will snap into Access
Panel Support Bracket.
If you have any difficulties installing or servicing your
Draper, Inc. | 411 S. Pearl St. Spiceland, IN 47385
draperinc.com | 765.987.7999 | 800.238.7999
|
© 2019 All Rights Reserved
FORM: AccessFit_Inst18
(See
(2)
hex head
fully
(one on