BD Sensors BAROLI 05 Instrukcja montażu - Strona 2
Przeglądaj online lub pobierz pdf Instrukcja montażu dla Przyrządy pomiarowe BD Sensors BAROLI 05. BD Sensors BAROLI 05 2 stron. Digital pressure gauge
Również dla BD Sensors BAROLI 05: Instrukcja obsługi (2 strony)
D
E
Montageanleitung /
Mounting instructions
Digitalmanometer / Digital pressure gauge
BAROLI 02, 02 P, 05, 05 P
www.bdsensors.com
Headquarters
Eastern Europe
BD SENSORS GmbH
BD SENSORS s.r.o.
BD-Sensors-Str. 1
Hradištská 817
D - 95199 Thierstein
CZ - 687 08 Buchlovice
Germany
Czech Republic
Tel.: +49 (0) 9235-9811-0
Tel.: +42 (0) 572-4110 11
Fax: +49 (0) 9235-9811-11
Fax: +42 (0) 572-4114 97
Russia
China
BD SENSORS RUS
BD SENSORS China Co, Ltd.
39a, Varshavskoe shosse
Room B, 2nd Floor, Building
RU - Moscow 117105
10, No. 1188 Lianhang Rd.
201112 Shanghai,
Russia
China
Tel.: +7 (0) 95-380 1683
Tel.: +86 (0) 21-51600 190
Fax: +7 (0) 95-380 1681
Fax: +86 (0) 21-33600 613
Diese Montageanleitung stellt einen Auszug
aus der ausführlichen Betriebsanleitung dar.
Bitte laden Sie sich diese auf unserer Home-
page herunter, falls Sie nicht mit dem Produkt
vertraut sind.
These mounting instructions are an excerpt from the complete
operating manual. It may be downloaded from our homepage, if
you are not familiar with the device.
http://www.bdsensors.de
http://www.bdsensors.com
– Technische Änderungen vorbehalten –
– Technical modifications reserved –
Englisch
WARNING! In order to avoid hazards to operators and
damages to the device, the following instructions have to
be performed by qualified technical personnel.
WARNING! Adhere to the safety and operating instructions
stated in the operation manual. Effective regulations on oc-
cupational safety, accident prevention as well as national
installation standards and approved engineering tech-
niques must in addition be complied with.
Limitation of liability
If the instructions in the operating manual are not adhered
to or if the device is inappropriately used, modified or dam-
aged, liability is not assumed and warranty claims will be
excluded.
Intended use
Ensure that the medium is compatible with the media-
wetted parts and that the device is suitable for the applica-
tion without restrictions. The technical data listed in the cur-
rent data sheet is binding.
Product identification
Type designation
Ordering code
Serial
Input
number
Changing the batteries
To change the batteries go ahead
plastic cap above
as follows:
battery case
- Turn the plastic cap 45° anti
clockwise by a coin (e.g. 2 € coin)
as far as possible.
- Hold the count tight and lever the
plastic cap out of the housing with
help of the count.
- Take the cap off and change the
batteries.
- Lock the device after that prop-
erly.
Display and operating module
limit exceeding
neg. / pos.
symbol for
measured value
indicate low
batteries
unit
Mounting
WARNING! Install the device only in depressurized and currentless state!
WARNING! Use a suitable seal, corresponding to the medium and the pressure input.
DO NOT USE ANY ADDITIONAL SEALING MATERIALS; LINKE YARN; HEMP OR TEFLON TAPE
(for connection acc. DIN 3852)!
Connection acc. to DIN 3852
G1/4": approx. 5 Nm
G1/2": approx. 10 Nm
G1":
approx. 20 Nm
The indicated tightening torques must not be exceeded!
Dairy pipe connection
Clamp and Varivent
- Centre the connection
- Centre the connection in the
in the mounting part.
mounting part.
- Screw the cup nut onto the
- Fix the device with a suitable fastening
mounting part.
element (e. g. semi-ring or retractable
- Then tighten it with a hook wrench.
ring clamp) according to the supplier's
instructions.
Take note that no inadmissibly high mechanical stress occurs at the pressure port, since this may cause a shifting of the
characteristic curve or to the demage. This is especially important for very small pressure ranges as well as for devices with a
pressure port made of plastic.
For more information, please read the detailed operating manual!
Structure of the menu system
▲ / on button: turn the device on
move forward in the menu system
increase the displayed value
▼ / off button: turn the device off
move backward in the menu system
decrease the displayed value
OK button:
activate the operating mode and the
different menu items
confirm the set values
Connection acc. to EN 837
NPT connections
G1/4": approx. 20 Nm
1/4" NPT: approx. 30 Nm
G1/2": approx. 50 Nm
1/2" NPT: approx. 70 Nm
connection
Flange connection
Fasten the flange with 4 resp.
8 screws (depending on
flange version) on the counter
flange.