1.3 DESIGN AND GENERAL HEATER DIMENSIONS

The heater tanks are made of a steel plate and tested at 0.9 MPa of overpressure. The inside of the tank is
enamelled. A flange is welded onto the bottom of the tanks with a flange lid screwed to it.
A sealing ring is inserted between the flange lid and the flange. Thermowells for placing a heating element,
thermostat sensors and safety fuses are located in tone flange lid, and the safety fuses and the second
flange lids are without thermowells. An anode rod is mounted onto the M8 nut. Electric wiring is placed
underneath the plastic removable cover. Description of basic parts of the heater – Figure 1. Heater
dimensions - Figure 2.
1. Enamelled steel receptacle
2. Heater shell
3. Polyurethane insulation
4. The heating element well, ceramic heating unit 2000W, OKHE ONE 30 – 1100W
5. Thermostat sensor well and temperature indicator
6. Mg anode
7. Filling-in tube
8. Electric installation cover
9. Thermometer
10. Service thermostat with external control and safety fuse
11. Drain tube
Figure 1