ANDalyze AND1100 Podręcznik użytkownika - Strona 9

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Przyrządy pomiarowe ANDalyze AND1100. ANDalyze AND1100 16 stron. Fluorimeter for water testing

AND1100 Fluorimeter for Water Testing
 
Options 
 
Power Save: This sets the minutes when the display 
will turn black to save power.  Settable from 1 to 5 
minutes. 
 
Power Off: This is the minutes which the unit will 
turn itself off after it goes into power save mode.  
Settable from 6 to 15 minutes. 
 
Cuvette Removal: Turning this ON will cause a 
screen to appear after each test reminding the user 
to remove the cuvette from the sample chamber. 
 
Test Instructions: In the ON position, 4‐step 
instructions will display in order when Test is 
selected from the home screen.  After the 4
the test will begin.  In the OFF position, the testing 
begins immediately. 
 
Advanced 
 
User can View and Set parameters for each specific sensor.  Edit 
values using up/down keys and SELECT. 
 
Window: Determines the number of points that will be used to 
calculate the rate of fluorescence increase over time. We use a 
moving average method to calculate maximum rate. (If the value of 
window and samples is same, then the average slope is calculated) 
 
Samples: Total data points taken which determines time up to which 
data is collected. A value of 100 is approximately 20 seconds. Increase 
sample value, to increase data collection time.  Generally an increase 
in samples can increase sensitivity especially in matrices such as waste 
water. 
 
 
ANDalyze Inc. 800 Boylston Street, Prudential Tower, Floor 16, Boston, MA 02199 USA Tel. +1 857.453.6740 www.andalyze.com 
th
 step, 
 
 
Sensor Lot: Turning this option ON allows the user to 
enter the lot number of the sensors at the time of a 
site calibration.  This helps to identify when a new site 
calibration is required (new lot batch). 
 
Temperature: Turning this option ON allows the user 
to enter the temperature of the sample water at the 
time of a site calibration.  This helps to identify when a 
new site calibration is required (significant change in 
water temperature). 
 
Temperature Units: Switch between Celsius and 
Fahrenheit for temperature entry and displays. 
 
Display Contrast: Adjusts the brightness of the display.  
Higher value indicates a brighter display. 
 
Language: Choose between English, Chinese, 
Portuguese, Spanish and German languages for the 
fluorimeter displays. 
 
 
Page 9 of 16 
 
 
 
 
 
July 1, 2013