ATI Technologies 39-0050 Instrukcja instalacji i obsługi - Strona 19

Przeglądaj online lub pobierz pdf Instrukcja instalacji i obsługi dla Przyrządy pomiarowe ATI Technologies 39-0050. ATI Technologies 39-0050 19 stron. Digital control installation & operation

ATI Technologies 39-0050 Instrukcja instalacji i obsługi
24volt Feeder Connections using Existing 24volt Power Supply and ATL Control Power Supply. WestFalia 'M' type feeder
WITHOUT
integral ballast resistor.
Existing 24v Power Supply
Output: 24volts AC or DC
Relay and Connector fitted
to the base of the Digital Control
Double Digital Controls are fitted with 2
Trigger Relays and a 3 way connector in the
base of the enclosure. One connector is a
common Negative 24volts DC
and the other two are the trigger outputs to
the feeder connector blocks.
Fuse: In-line 2A
Feeder Connector Block Assembly
Figures in square brackets refer to minimum cable csa (mm2 ).
24volts AC or DC to ATL Control Power Supply [2.5]
ATL Control
Power Supply
5
88
Digital Feeder Control
8
Fit 12 Ohm 1 watt resistor between
green and brown.
!
M
DATA SHEET: 23B
DIGITAL CONTROL
WS NO RESISTOR
1
7
6
Check that the motor is
Integral Ballast Resistor
Green (+)
Brown (+)
Grey (Trig)
White (-)
Yellow (-)
NOT
fitted with an