ATI Technologies 39-0050 Manuel d'installation et d'utilisation - Page 19

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} ATI Technologies 39-0050. ATI Technologies 39-0050 19 pages. Digital control installation & operation

ATI Technologies 39-0050 Manuel d'installation et d'utilisation
24volt Feeder Connections using Existing 24volt Power Supply and ATL Control Power Supply. WestFalia 'M' type feeder
WITHOUT
integral ballast resistor.
Existing 24v Power Supply
Output: 24volts AC or DC
Relay and Connector fitted
to the base of the Digital Control
Double Digital Controls are fitted with 2
Trigger Relays and a 3 way connector in the
base of the enclosure. One connector is a
common Negative 24volts DC
and the other two are the trigger outputs to
the feeder connector blocks.
Fuse: In-line 2A
Feeder Connector Block Assembly
Figures in square brackets refer to minimum cable csa (mm2 ).
24volts AC or DC to ATL Control Power Supply [2.5]
ATL Control
Power Supply
5
88
Digital Feeder Control
8
Fit 12 Ohm 1 watt resistor between
green and brown.
!
M
DATA SHEET: 23B
DIGITAL CONTROL
WS NO RESISTOR
1
7
6
Check that the motor is
Integral Ballast Resistor
Green (+)
Brown (+)
Grey (Trig)
White (-)
Yellow (-)
NOT
fitted with an