Anderson FFO57 Instrukcja obsługi - Strona 6

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Palnik Anderson FFO57. Anderson FFO57 8 stron.

Burner dimension and inlet interface:
Burner Model
57G1000
57G1500
57G2000

5.2 Burner adjustment

On the non-combustion side, open the quick disassembly connector before installation and secure
the front sleeve part to the furnace wall. Position the burner retaining ring to the burner and firmly
with fastening screws. Then secure the burner and casing together using the quick removal
connector. Locch the burner to ensure the front of the burner does not extend the casing and
retreat for 1-5cm. Connect the burner main gas hose, main oxygen hose, ignition gas hose, ignition
oxygen hose, install the flame detector and wiring, connect the spark plug. Open all hand
regulating valves, adjust the cooling air flow, and check to ensure that all hoses are properly
connected.

6. Burner Maintenance

Burners require routine inspection. Examination after the first or long absence are particularly
important.
For the first use, check that the seal of each interface is intact and not loose. After the burner is first
used normally, the burner needs to be checked. In the first month, the burner, the spark plugs, the
flame detectors are checked on the week, and the inspection frequency can be extended to once two
weeks in the second month. Anderson suggested that the burner check out at least once a month.
Each inspection requires the inspection when the system is down and has cooled to room
temperature.

7. Spare Parts

For normal use and regular maintenance of the burner, we recommend preparing the following parts:
– Flame Detector
– Spark Rod
– Burner Spare Sleeve
Anderson Thermal Soluions(Suzhou)Co., Ltd
Input kW
A(mm)
B(mm)
1MW
1000
1.5MW
895
2MW
805
Anderson Thermal Solutions – FFO57 Operation Manual
C(mm)
D(mm)
1323
57
DN50
1215
65
DN50
1267
73
DN50
4
E(mm)
DN32
DN40
DN40