INSTALLATION AND OPERATION MANUAL
INSTALLATION AND OPERATION MANUAL
Installation Instructions (Continued)
7 - CONNECT POWER
Connect power to unit per the following table.
Table 3 – Power Connections per Use Case
Operating Voltage
Use Power Connectors
Contact the ComNet Design Center, or refer to the appropriate installation and operation manual when configuring and specifying power for a deployment.
8 - VERIFY FUNCTIONALITY
See LED Indicator table below and Troubleshooting Guide if corrective action is needed.
Table 4 – Front Panel LED Indicators
SFP Link
GREEN
Solid
Communication link has been established
over optical fiber. Flashes when data is
being transmitted.
Flashing
Fiber failure or copper failure (Link Fault
Enable must be switched set to ON)
Dim
–
Bright
–
RED
Solid
–
OFF
Communication link has not been
established.
Figure 5 – Electrical Port
Ethernet
Ethernet
Speed
Link /
Activity
Figure 6 - Fault Relay Operation
The fault relay is normally closed and will open on any of the following alarm conditions:
- Link Fault is enabled on the remote RLMCSFP unit and the corresponding copper port has been
disconnected.
- Link Fault is enabled on the local RLMCSFP unit and the corresponding copper port has been
disconnected.
- Fiber Fault is enabled on the local RLMCSFP unit and the fiber link is down or the power has been lost to
either the local or remote RLMCSFP unit.
TECH SUPPORT: 1.888.678.9427
RLMCSFP24DC
Redundant Inputs
9 to 36 VDC (max)
Vin1+ and Vin1- for PS 1
Vin1+ and Vin1- for PS 1
Vin2+ and VIN2- for PS 2
Vin2+ and VIN2- for PS 2
Table 5 – Electrical Port LED Indicators
Link / Activity
GREEN
Solid
Flashing
YELLOW
–
OFF
Communication link has not been established.
RLMCSFP48DC
88 to 300 VDC (max)
Redundant Inputs
36 to 59 VDC (max)
85 to 264 VAC (max)
SFP Speed
1000 Mbps
–
–
–
100 Mbps
Unit is not correctly powered up or DIP
Switch incorrectly set.
(Reset power after switch change.)
Communication link has been established over the electrical cable
Data is being transmitted over the electrical cable
RLMCSFP SERIES
RLMCSFP SERIES
RLMCSFPHV
RLMCSFPPOEHO
Redundant Inputs
OR
44 to 57 VDC (max)
+/L, -/N,
Vin1+ and Vin1- for PS 1
and Earth GND
Vin2+ and VIN2- for PS 2
Fault
Power
No Fault (NC-
Power Applied
COM)
–
–
–
–
–
–
Fault (NO-COM)
–
Unit is not
Unit is not
correctly
correctly
powered up
powered up
PoE
–
–
30 W Mode
60 W Mode
-
-
Speed
–
–
1000 Mbps Speed
10/100 Mbps Speed
INS_RLMCSFP_REV–