During operation

1. Has the installation / putting into operation been carried out successfully in accordance
with the present instructions and guidelines?
2. Check the first heating-up phase exactly and monitor the further operation of the heated
hose.
3. Make sure that the fluid at the inflow or inlet point is not hotter than the max.
Permissible heated hose temperature, otherwise the heated hose could suffer damage at
this point.
4. Extreme movements or vibrations, shaking etc. should be avoided during operation of
the heated hose.
5. If you want to remove the heating hose, you should first check that the hose has cooled
down and that it is totally disconnected from the mains power supply.
6. The fitting should never be used to pull the heated hose; the fittings are resistant to
pressure, but more susceptible to tension forces.
7. It can happen that a fitting becomes clogged up when the liquid hardens and that the
fitting only becomes unclogged after a certain heating-up period. Do not try to shorten this
waiting period by applying heat externally (e.g. using a burner etc.). This will damage the
heated hose, and waiting for a replacement delivery will certainly take longer!
8. If you notice any damage to the heated hose or abnormal functioning during operation,
the hose must be switched off and disconnected from the power supply immediately. For
this purpose a disconnection device (master switch) with a minimum contact gap of 3mm is
to be provided by the customer together with a 16A or 20A fuse depending on the lead
cross-section. Any fault needs to be exactly analysed in order to determine the cause. Our
experienced specialists will be pleased to assist you.
9. Avoid exposing the hose to direct solar radiation for any length of time or, if unavoidable,
provide suitable protection.