DROPSA VIP4ToolsPro Instrukcja obsługi i konserwacji - Strona 5
Przeglądaj online lub pobierz pdf Instrukcja obsługi i konserwacji dla Systemy smarowania DROPSA VIP4ToolsPro. DROPSA VIP4ToolsPro 12 stron.
6.6 ELECTRICAL CONNECTIONS
The only electrical connection required is that of the Samba level. (see paragraph 4 Technical
specifications)
6.6.1 Schematic electrical connection Samba Level
NC electric level in the absence of lubricant.
6.6.2 Schematic electrical solenoid connection
Connector 39979- EV 24 V DC non polarized.
N.B.: After all connecting up has been completed ensure the tubing and cables are protected from
impacts and are suitably secured.
5