To go to the home screen
Press the
button to return to the home screen.
4.3.2

Using the menu structure

About the menu structure
Go to the menu structure to change the settings of the unit and read
out values such as the current temperature. For an overview of the
settings available to the user, see
user settings" on
page 16.
To go to the menu structure
Press
to go to the menu structure.
4.3.3

Turning operation ON or OFF

4.4

Space heating control

4.4.1

About space heating control

Controlling space heating typically consists of the following stages:
1

Setting the space operation mode

2
Controlling the temperature
Depending on the system layout and installer configuration, you use
a different temperature control:
▪ Room thermostat control
▪ Leaving water temperature control
▪ External room thermostat control
4.4.2
Setting the space operation mode
About space operation modes
This unit is a heating only model. The system can heat up a space,
but NOT cool down a space.
4.4.3
Determining which temperature control
you are using
To determine which temperature control you are using
(method 1)
Check the installer settings table filled in by the installer.
To determine which temperature control you are
using (method 2)
You can see on the home screen which temperature control you are
using.
18 Feb 2018
55
a2
18
b
21
1.6
bar
a1
45
a1
Heat emitter of the main zone (in this example Underfloor
heating)
a2
Heat emitter of the additional zone (in this example
Radiator). If no icon is displayed, there is no additional
zone.
b
Room thermostat type of the main zone:
If b=...
Then the temperature control is...
Main zone
Room thermostat
control
External room
thermostat control
EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ
Daikin Altherma 3 R F
4P495251-1B – 2019.06
"4.9  Menu structure: Overview
22:19
6
Additional zone (if
any)
External room
thermostat control
If b=...
Then the temperature control is...
Main zone
No icon
Leaving water
temperature control
4.4.4

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.
1 Go to [1]: Room.
1
Room
2 Adjust the desired room temperature.
a
b
1
21
°C
Room
a Actual room temperature
b Desired room temperature
If scheduling is on after changing the desired room temperature
▪ The temperature will stay the same as long as there is no
scheduled action.
▪ The desired room temperature will return to its scheduled value
whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off
scheduling.
To turn off room temperature scheduling
1 Go to [1.1]: Room > Schedule.
2 Select No.
4.4.5
To change the desired leaving water
temperature
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Only adjust the leaving water temperature settings in case
of problems.
You can use the leaving water temperature setpoint screen to read
out and adjust the desired leaving water temperature.
4 Operation
Additional zone (if
any)
Leaving water
temperature control
+
User reference guide
7