4 Operation
1 Go to [2]: Main zone or [3]: Additional zone.
2
Main zone
3
Additional zone
2 Adjust the desired leaving water temperature.
a
b
2
35
°C
Main zone
a
b
3
45
°C
Additional zone
a Actual leaving water temperature
b Desired leaving water temperature
If scheduling is on after changing the desired leaving water
temperature
▪ The temperature will stay the same as long as there is no
scheduled action.
▪ The desired leaving water temperature will return to its scheduled
value whenever a scheduled action occurs.
You can avoid scheduled behaviour by (temporarily) turning off
scheduling.
To turn off leaving water temperature scheduling
1 Go to one of the following:
▪ [2.1]: Main zone > Schedule
▪ [3.1]: Additional zone > Schedule
2 Select No.
To enable weather-dependent operation for the leaving water
temperature
See
"4.8 Weather-dependent operation" on
4.5

Domestic hot water control

4.5.1

About domestic hot water control

Depending on the DHW tank mode (installer setting), you use a
different domestic hot water control:
▪ Reheat only
▪ Schedule + reheat
▪ Schedule only
User reference guide
8
+
+
page 14.
CAUTION
The backup heater permission schedule is used to restrict
or allow backup heater operation based on a weekly
program.
Advice:
In
disinfection function, at least allow the backup heater (by
the weekly program) for minimum 4 hours starting from the
scheduled start-up of disinfection. If the backup heater is
restricted during disinfection, this function will NOT be
successful and the applicable warning AH will be
generated.
INFORMATION
In case of error code AH and no interruption of the
disinfection function occurred due to domestic hot water
tapping, following actions are recommended:
▪ When the Reheat only or Schedule + reheat mode
is selected, it is recommended to program the start-up
of the disinfection function at least 4  hours later than
the last expected large hot water tapping. This start-up
can be set by installer settings (disinfection function).
▪ When the Schedule
recommended to program an Eco action 3 hours before
the scheduled start-up of the disinfection function to
preheat the tank.
To determine which domestic hot water mode you are using
(method 1)
Check the installer settings table filled in by the installer.
To determine which domestic hot water mode you are using
(method 2)
1 Go to [5]: Tank.
2 Check which items are displayed:
[5.1]
Powerful operation
[5.2]
Comfort setpoint
[5.3]
Eco setpoint
[5.4]
Reheat setpoint
[5.5]
Schedule
If... is displayed
Then the DHW tank mode =...
Only [5.1] Powerful
Reheat only
operation
All items except [5.4]
Schedule only
Reheat setpoint are
displayed
All items including [5.4]
Schedule + reheat
Reheat setpoint are
displayed
4.5.2

Reheat mode

In reheat mode the DHW  tank continuously heats up to the
temperature shown on the home screen (example: 50°C) when the
temperature drops below a certain value.
T t
1
60°C
50°C
40°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
EHVZ04+08S18+23DA + EHVZ04+08S18+23DJ
order
to
avoid
unsuccessful
only mode is selected, it is
3
2
4
t
14:00
21:00
Daikin Altherma 3 R F
4P495251-1B – 2019.06