6. Performing a real test
Testing triggering when there is an attempt to remove the siren
IMPORTANT: the sound level of the siren can cause hearing disorders. The necessary precautions must therefore be taken
before testing siren triggering.
1. Loosen the siren locking screw.
2. Open the siren.
3. Check triggering:
• of the siren
• of the control panel
• of the telephone dialler
4. Issue an Off order.
7. Maintenance
7.1 Fault indications
The control panel supervises and identifies the siren.
It monitors the state of the:
• power supply,
• radio link,
• tamper contact.
If a fault is memorised the control panel issues a voice message to indicate the fault following a system command (see §
Fault indications in the control panel installation manual).
7.2 Changing the battery
• The lithium battery pack must be replaced by the same type of pack with the same technical characteristics,
i.e. 2 x (3.6 V – 13 Ah).
• We advise you to use the DAITEM BatLi22 pack available in the catalogue in order to guarantee individual safety
and equipment reliability.
• Dispose of the waste lithium power pack in an appropriate recycling bin.
To change the battery:
1. send a disarm command,
2. switch the control panel to installation mode:
master code
3. remove the siren from the wall,
4. remove the faulty lithium power pack,
5. wait for 2 minutes before connecting the new lithium pack,
6. close the siren and put it back on its base,
7. switch the control panel to user mode:
installer code
8. test triggering.
then
installer code
10