8. Summary of parameters
Parameter description
Delayed sounding
upon intrusion
Sounding duration
Flashing duration
Type of sounding
Sound level of disarm/arm
indications
Transfer of disarm/arm
indications
Indication of audible signals
and door bell
Validation of radio link
in installation mode
Sounding level
Triggering upon intrusion
Protection system armed
indication
Alarm indication in armed
presence mode
Triggering upon communication ** 4 * siren n° * 26 * ? **
network interruption
Radio tamper
Indication of break-in following ** 4 * siren n° * 35 * ? **
intrusion
Visual localisation of flashing
following intrusion
Allocation of a siren to one
or several intrusion groups
Type of warning indication
Type of deterrence indication
Type of prealarm indication
Anti-tamper switch triggering
Deletion of all parameters
Deletion of one parameter
Parameter-setting sequence
** 4 * siren n° * 3 * ?? **
** 4 * siren n° * 4 * ??? **
** 4 * siren n° * 5 * ?? **
** 4 * siren n° * 10 * ? **
** 4 * siren n° * 11 * ? **
** 4 * siren n° * 12 * ? **
** 4 * siren n° * 13 * ? **
** 4 * siren n° * 15 * ? **
** 4 * siren n° * 19 * ? **
** 4 * siren n° * 20 * ? **
** 4 * siren n° * 21 * ? **
** 4 * siren n° * 22 * ? **
** 4 * siren n° * 27 * ? **
** 4 * siren n° * 36 * ? **
** 4 * siren n° * 37 * ? **
** 4 * siren n° * 72 * ? **
** 4 * siren n° * 73 * ? **
** 4 * siren n° * 74 * ? **
** 4 * siren n° 75 * ? **
** 4 * siren n° * 197 ***
** 4 * siren n° * parameter n° ** 0 **
Factory
parameter
0: immediate
from 0 to 60 s
0: immediate
90 s (60 s Spain)
from 20 s to 180 s
15 min
from 1 to 60 min
external
0: internal
1: external
4: average
from 1 to 8
0: disabled
0: disabled
1: sounding
3: sounding and flashing
5: flashing
0: disabled
0: disabled
1: enabled
0: on one
0: validation on 1 of 2 bands
of 2 bands
1: validation on 2 bands
0: normal
0: normal
1: quiet
1: single
0: disabled
or confirmed
1: single or confirmed intrusion
intrusion
2: confirmed intrusion only
1: disabled
0: disabled
1: sounding
2: loud sounding
0: disabled
(15 s)
1: quiet sounding (4 beeps)
2: loud sounding (15 s)
4: quiet sounding (4 beeps)
and flashing
5: loud sounding (15 s) and flashing
7: flashing
0: disabled
0: disabled
1: loud sounding triggered
if the system is totally armed
2: loud sounding triggered 24/24
1: enabled
0: disabled
1: enabled
0: disabled
0: disabled
1: enabled
2: enabled 24 h
0: disabled
0: disabled
1: enabled 2 h
2: enabled 48 h
all groups
Selection of group(s): from 1 to 8
depending on type of control panel
3: flashing
0: disabled
1: sounding
2: sounding and flashing
3: flashing
2: sounding
0: disabled
and flashing
1: sounding
2: sounding and flashing
3: flashing
2: sounding
0: disabled
and flashing
1: sounding
2: sounding and flashing
3: flashing
1: enabled if
0: enabled 24 h/day
system totally
1: enabled if system totally armed
armed
11
Possible values
Page
3
4
5
4
4
4
4
4
4
4
5
5
5
5
5
6
7
7
7
7
7
8
8