DSC TL280R Instrukcja instalacji - Strona 10
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla System bezpieczeństwa DSC TL280R. DSC TL280R 16 stron. Internet alarm communicator - international
Również dla DSC TL280R: Instrukcje instalacji (17 strony), Instrukcja instalacji (16 strony)
Trouble
Trouble Indic-
Indicator
ation
Digit
Yellow LED
–
08
8 Flashes
Yellow LED -
09
9 Flashes
Yellow LED
–
0C
12 Flashes
Red and
Yellow LEDs
N/A
flashing
together
.
The programming sections described in this document can be viewed at the keypad LCD. To start programming enter: [*][8]
[installer code][851][section number], where section number is the 3-digit section number referenced in this section. The pro-
gramming worksheets at the end of this document can be used to record the new values when programming changes have
been made from the default values.
Possible
Causes
address and port number.
Receiver
This trouble is indicated when supervision is enabled and the unit is not able to
l
Supervision
successfully communicate with the receiver.
If this trouble persists, contact the central station.
Trouble
l
The unit has exhausted all communications attempts to all programmed
l
FTC Trouble
receivers for events generated by the communicator.
Restart the system, if trouble persists, contact the dealer.
l
Module
This indication appears when section [021] system account code or sections
l
[101] or [111] receiver account code have not been programmed. Ensure that a
Configuration
valid account code has been entered in these sections.
Trouble
The unit is still initializing please wait while the unit gets its programming and
l
Initialization
establishes a connection to all programmed receivers.
Sequence
NOTE: This process may take several minutes to complete.
If the initialization sequence is taking more than several minutes, the boot loader
l
might have failed.
Confirm that the boot loader has failed by entering communicator programming
l
Boot Loader
[*][8][installer code][851].
Failed
If access is granted, continue waiting for the initialization sequence to complete.
l
If access is denied (long error tone), disconnect power from, then reconnect
l
power to the communicator module.
Ethernet Programming Options
Trouble Possible Solution
10