DAN DRYER 288 Podręcznik użytkownika - Strona 4
Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Suszarka DAN DRYER 288. DAN DRYER 288 6 stron. Stainless design turbo hand dryer
PRODUCT APPLICATION
• Shake excess water from hands
• Place hands under the dryer to turn it on
• Rub hands lightly and rapidly
• Stops automatically after hands are removed.
RECOMMENDED INSTALLATION HEIGHT
From bottom edge of hand dryer above finished floor.
Men
1270 mm
(50")
Women
1194 mm
(47")
Children 4-7 years
889 mm
(35")
Children 8-10 years
991 mm
(39")
Children 11-13 years
1092 mm
(43")
Children 14-16 years
1194 mm
(47")
Wheelchair users
1016 mm
(40")
CLEANING AND MAINTENANCE
Routine cleaning and maintenance is recommended every 12 months.
• Cut the power
• Unscrew (2) bottom security screws
• Remove the cover
• Clean the cabinet inside and remove dust/dirt. You can use compressed air
• Check carbon brushes in the motor. If carbon brushes are worn (≤ 10 mm graphite
remaining), they must be replaced
• Clean sensor lense on both sides
• Do not rinse with running water
• Use a damp cloth and mild cleaning solution. Never use cleaning detergents with an
abrasive effect
• Replace cabinet front and tighten screws. Be careful not to overtighten screws
6
ADJUSTMENT OF AIR SPEED AND TEMPERATURE
• Insert Philips screwdriver or flat notch through the hole at the bottom of the cover and
place the screw head on the potentiometer screw (see drawing below)
• Adjust air speed and temperature on the VR potentiometer:
Clockwise to increase air speed and temperature (+)
Counterclockwise to decease air speed and temperature (-)
• Be careful not to overturn the adjustment screw
ADJUSTMENT OF SENSOR RANGE
The sensor range is adjsutable between 100 mm and 230 mm. Standard range 170 mm
± 20 mm.
• Switch off power and dismount the cover by loosening (2) screws at the bottom
• Use a small Philips screwdriver or similar to adjust the sensor on the VR screw:
Clockwise to increase sensor activation range (+)
Counterclockwise to decrease sensor activation range (-)
• The sensor activation range should be adjusted to its environments, e.g. light and
distance to the bottom of the sink
• Be careful not to overturn the sensivity adjustment
7