4. Electrical connection
4.1 Connecting the DAC operating panel
Attention!
All work on the electrical equipment of the sewing machine must be
carried out by specialist electricians or other appropriately-trained
persons.
The mains plug must be removed.
The DAC operating panel 1 is mounted on the right-hand side of the
machine, seen from the operator's viewpoint.
1
–
Fit operating panel 1 with clamps 4 and 6 to attachment bracket 5
and adjust angle.
–
Firmly tighten clamping screws on clamps 4 and 6.
Attach potential cable 3 to clamp 4.
The function of the potential cable is to discharge static charges to
earth.
–
Slightly undo lock nut 7 on attachment bracket 5.
–
Rotate operating panel 1 until the operator has the best possible
view of the display.
–
Firmly tighten lock nut 7.
–
Carefully insert plug 2 into the back of the operating panel.
–
Tighten screws of plug 2.
2
3
4
5
6
7
13