Duerkopp Adler 745-26 Руководство по установке - Страница 13

Просмотреть онлайн или скачать pdf Руководство по установке для Швейная машина Duerkopp Adler 745-26. Duerkopp Adler 745-26 18 страниц.

Duerkopp Adler 745-26 Руководство по установке

4. Electrical connection

4.1 Connecting the DAC operating panel

Attention!
All work on the electrical equipment of the sewing machine must be
carried out by specialist electricians or other appropriately-trained
persons.
The mains plug must be removed.
The DAC operating panel 1 is mounted on the right-hand side of the
machine, seen from the operator's viewpoint.
1
Fit operating panel 1 with clamps 4 and 6 to attachment bracket 5
and adjust angle.
Firmly tighten clamping screws on clamps 4 and 6.
Attach potential cable 3 to clamp 4.
The function of the potential cable is to discharge static charges to
earth.
Slightly undo lock nut 7 on attachment bracket 5.
Rotate operating panel 1 until the operator has the best possible
view of the display.
Firmly tighten lock nut 7.
Carefully insert plug 2 into the back of the operating panel.
Tighten screws of plug 2.
2
3
4
5
6
7
13