Cascade 120C Instrukcja instalacji - Strona 3
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla Wózki widłowe Cascade 120C. Cascade 120C 10 stron.
T
RUCK REQUIREMENTS
WARNING: Rated capacity of the truck/
attachment combination is a responsibility of the
original truck manufacturer and may be less
than that shown on the attachment nameplate.
Consult the truck nameplate.
Truck Relief Setting
2000 psi (140 bar) Recommended
2300 psi (160 bar) Maximum
Truck Flow Volume
Min.
55C, 100C,
5 GPM
120C, 150C (19 L/min.)
Cascade C-Series Fork Positioners are compatible with SAE
10W petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-
5606 or MIL-0-2104B. Use of synthetic or aqueous base
hydraulic fluid is not recommended. If fire resistant hydraulic
fluid is required, special seals must be used. Contact Cascade.
Flow less than recommended can result in slow and unequal
fork movement.
Flow greater than maximum can result in excessive heating,
reduced system performance and short hydraulic system life.
Carriage Mount Dimension (A)
A
Class II
14.94 in. (380.0 mm)
Class III 18.68 in. (474.5 mm)
Class IV 23.44 in. (595.5 mm)
GA0028.ill
Auxiliary Valve Functions
Check for compliance with ITA (ISO) standards:
GA0082.ill
Recommended
Max.
7 GPM
10 GPM
(26 L/min.)
(38 L/min.)
Minimum
Maximum
15.00 in. (381.0 mm)
18.74 in. (476.0 mm)
23.50 in. (597.0 mm)
Tilt
Forward
Spread Forks
Sideshift
Hoist Down
Left
Hoist Up
Sideshift
Right
Tilt
Close Forks
Back
ITA (ISO)
Carriage
Clean carriage bars and inspect for
damaged notches
GA0080.ill
1