Casio 2198 Podręcznik ogólny - Strona 7

Przeglądaj online lub pobierz pdf Podręcznik ogólny dla Oglądaj Casio 2198. Casio 2198 9 stron.

Casio 2198 Podręcznik ogólny
To calibrate the temperature
1. Display the barometric pressure/tempera-
A
B
2. Hold down A until the display clears.
hPa mb
°
• The "OFF" indicator appears when the
C
factory setting is being used for the
A S
calibration.
C
D
E
3. Each press of D increases the displayed
hPa mb
TEMP ADJ
°
TEMP ADJ
C
°
C
A S
• Any time you calibrate the temperature, the message "TEMP ADJ" appears
on the display. This message remains on the display in any mode in which
the temperature is displayed.
• If you have selected Fahrenheit as your unit of measurement, the above
operations change the reading by 0.2°F.
• Pressing B and D at the same time returns to the "OFF" display.
4. After calibrating the temperature, press A to return to the Barometric
Pressure/Temperature screen.
• If you do not operate any button for a few minutes while the temperature
digits are flashing, the flashing stops and the watch goes back to the
Barometric Pressure/Temperature screen.

WARNING INDICATORS

Warning indicators appear whenever any of the conditions described below
occur. Appearance of a warning indicator causes any measurement operation
that is currently underway to stop. Warning indicators appear in the upper
display, and this causes "– – –" to replace any directional, altitude, barometer,
or temperature values on the display.
Abnormal Magnetic Field Indicator
This indicator appears whenever the Digital
Compass has a problem obtaining a correct
reading. This condition could indicate that
the watch is within a very high magnetic field,
and so you should try moving to another
location. Also, see "Digital Compass
Precautions" for further information on
conditions that cause errors.
Low Battery Indicator
This message indicates that battery power is
too low to perform the measurement. It
appears whenever battery power drops below
a certain level, or when you try to use this
watch under very cold conditions (below about
–10.0°C/14.0°F).
If the "BAT" message appears because of use under cold conditions, it should
clear (and normal operation should return) after the watch is brought back to
normal temperature.
If battery power is low (indicated "BAT" appears under normal temperatures),
you should have the batteries replaced as soon as possible. Note that
replacement of the batteries causes all memory contents to be cleared.
Sensor Malfunction Indicator
This message indicates malfunction of
pressure sensor circuitry. Whenever a sensor
malfunction initially occurs, the "ERR"
messages flashes on the display and a buzzer
sounds for three seconds.
Note that calibrating the Digital Compass may cause the "ERR" message to
appear. In this case, the message does not indicate sensor malfunction, and
should be corrected if you re-calibrate the Digital Compass.
Important!
• If the sensor is malfunctioning when it comes time for a barometric pressure
measurement to be taken, the barometric pressure value appears as
"– – – –" on the display and the corresponding point on the barometric
pressure graph is left blank.
• There may be cases where the "ERR" or "BAT" message is cleared once
you change modes. In this case, you can continue using the watch normally
unless the error warning message reappears.
Whenever there is a sensor malfunction, be sure to take the watch to an
authorized CASIO distributor or Service Center as soon as possible.
ture in the Timekeeping Mode.
"OFF" or the temperature value should be
flashing on the display.
temperature by 0.1°C while pressing B
decreases it. Holding down either button
changes the value at high speed.

ALARM FUNCTIONS

Mode indicator
Five independent daily alarms can be set.
Alarm No.
Each alarm lets you set the hour and minutes.
When the Daily Alarm is on, the alarm sounds
A
B
for 20 seconds at the preset time each day.
Press any button to stop the alarm after it
starts to sound.
When the Hourly Time Signal is on, the watch
beeps every hour on the hour.
• In the Alarm Mode, the segments in the
A
graphic display create a rotational
C
D
movement effect while an alarm is sounding.
E
To set alarms
Hour Minutes
1. Use C to enter the Alarm Mode.
Graphic display
Alarm on
2. Press D to select Alarm 1 through 5.
indicator
Alarm 1
Alarm 2
Hourly Time Signal
3. After you select an alarm, hold down A until the hour digits flash on the
display. The hour digits flash because they are selected .
• At this time, the alarm is automatically switched on.
4. Press C to change the selection in the following sequence.
Hour
5. Press D to increase the selected digits and B to decrease them. Holding
down either button changes the selection at high speed.
• The format (12-hour or 24-hour) of the alarm time matches the format you
selected for normal timekeeping.
• When setting the alarm time using the 12-hour format, take care to set the
time correctly as morning (no indicator) or afternoon (P).
6. After you set the alarm, press A to return to the Alarm Mode.
To switch an alarm or the Hourly Time Signal on and off
1. In the Alarm Mode, press D to select an alarm or the Hourly Time Signal.
2. When the alarm or Hourly Time Signal you want to is selected, press E to
switch it on and off.
Indicates alarm is ON.
A
Indicates Hourly Time Signal is ON.
S
• If any alarm is on, the alarm on indicator (
you change to another mode.

To test the alarm

Hold down D while in the Alarm Mode to sound the alarm.
STOPWATCH FUNCTIONS
Mode indicator
The Stopwatch Functions let you measure
Graphic
elapsed time, split times, and two finishes.
display
1/100 second
The range of the stopwatch is 23 hours, 59
minutes, 59.99 seconds.
A
B
Stopwatch functions are available in the
Stopwatch Mode, which you can enter using
C.
• In the Stopwatch Mode, the graphic display
indicates the counting of seconds.
A S
C
D
E
Seconds
Hours
Minutes
(a) Elapsed time measurement
D
D
D
Start
Re-start
Stop
(b) Split time measurement
D
A
A
Split release
Start
Split
(c) Split time and 1st-2nd place times
D
A
D
Start
Split
Stop
Second runner finishes.
First runner
Record time of first runner.
finishes.
1998/2198-7
Alarm 3
Alarm 4
Alarm 5
Minutes
) is shown on the display when
A
A
D
Clear
Stop
A
D
Stop
Clear
A
A
Split release
Clear
Record time of
second runner.