9. Remove the O-rings and back-up rings
from the valve plate.
10. Mount the new back-up rings on the new
valve plate.
12. Carefully press, by hand, the cylinder
barrel onto the valve plate.
8. Carefully remove the valve plate assembly
using a screwdriver.
Mount backup
ring first
Then mount
O-ring
11. Mount the new O-rings.
13. Remove the port plate by hand.