2. Assembling the pump
© Danfoss | DCS (im) | 2017.06
Important: It is essential that the pump is
serviced in conditions of absolute cleanliness.
1. When mounting the port plate position
the port plate over the guide pin.
IMPORTANT: Make sure that the guide pin
is located in the locating hole in the port
plate.
3. Fit the retainer guide onto the shoulder of
the shaft.
4. Carefully position all the pistons into the
retainer plate.
6. Position the new white stop bush on top
of the retainer guide.
WARNING: Do not reuse disassembled O-ring
or shaft seal as they might be damaged.
Guide pin
2. Carefully slide the cylinder barrel into the
housing.
5. Position all the pistons, one in each piston
bore, in the cylinder barrel. It may be
necessary to tilt the retaining ring to allow
the pistons to fit into the piston bores.
7. Mount the new shaft seal following the
instructions in chapter 5 see page 8-11.