Danfoss iSave 21 Instrukcja serwisowa - Strona 10

Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Pompa wodna Danfoss iSave 21. Danfoss iSave 21 18 stron. Energy recovery device disassembling and assembling

Danfoss iSave 21 Instrukcja serwisowa
Service guide
10
Disassembling and assembling iSave 21
16.
Position the port plate over the guide pin.
O-ring
Guide pin
18.
Change the O-ring in the flange and
position the guide pin.
20.
Mount all bolts in the flange and tighten
them to a torque of 30 Nm ± 3 Nm.
180R9219 | 521B1171 | DKCFN.PI.003.K5.02 / 03.2016
17.
Check that the port plate fits the center
bearing and the guide pin.
19.
Position the port flange over the guide
pin.
21.
Wet the shaft seal with clean filtered
water.
Do not use silicone grease.
Fit the shaft seal with the carbon surface
upward.