Danfoss iSave 21 Instrukcja serwisowa - Strona 8
Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Pompa wodna Danfoss iSave 21. Danfoss iSave 21 18 stron. Energy recovery device disassembling and assembling
Service guide
8
Disassembling and assembling iSave 21
5.
Mount the high-pressure bearing
7.
Replace old O-ring with a new one
10
9.
Mount all bolts in the flange and tighten
them all with 30Nm±3
180R9219 | 521B1171 | DKCFN.PI.003.K5.02 / 03.2016
6.
Tighten the high-pressure bearing using
special socket and torque wrench with
90Nm±9
8.
Position the housing over the guide pin
10.
Fit the guide pin in the flange.