Danfoss iSave 21 Instrukcja serwisowa - Strona 14
Przeglądaj online lub pobierz pdf Instrukcja serwisowa dla Pompa wodna Danfoss iSave 21. Danfoss iSave 21 18 stron. Energy recovery device disassembling and assembling
Service guide
6.
Assembling the
vane pump
14
Disassembling and assembling iSave 21
1.
Position the guide pin.
3.
Position the side plate over the guide pin.
Note: Make sure that the guide pin is located
in the locating hole in the port plate. See #2
5.
Gently place the rotor in the bearing.
180R9219 | 521B1171 | DKCFN.PI.003.K5.02 / 03.2016
2.
Location hole in the side plate:
4.
Place the 4 pins in the rotor.
6.
Position the 8 vanes in the rotor.
The pins may be moved by using a
screwdriver.