6.
Assembling the
vane pump
14
Disassembling and assembling iSave 21
1.
Position the guide pin.
3.
Position the side plate over the guide pin.
Note: Make sure that the guide pin is located
in the locating hole in the port plate. See #2
5.
Gently place the rotor in the bearing.
180R9219 | 521B1171 | DKCFN.PI.003.K5.02 / 03.2016
2.
Location hole in the side plate:
4.
Place the 4 pins in the rotor.
6.
Position the 8 vanes in the rotor.