HEPA TOWER SPECIFICATIONS
Dimensions:
77 3/8" High x 27" Wide x 20 3/8" Deep
Weight:
172 lbs
Electrical:
120VAC, 60 Hz, Single Phase, 2.5A
Tested Airflow:
62 / 940 CFM (Low / High)
Tested Power:
10 / 272 Watts (Low / High)
Tested Noise*:
42 / 59 dBa (Low / High)
Controls:
Low Voltage, Digital Touch Controller, Optional Wireless Remote.
Speed Settings:
10
Timer:
12 Hours, in increments of 1 Hour.
Warranty:
3 years mechanical & structural parts, 1 year control parts.
* Tested at 45° and 1 meter from source
MAINTENANCE
• Replace The Tower's Pre-Filter every 2-3 Months.
Actual Size: 23 3/8" x 23 3/8" x 1 3/4" (or 3/4") MERV11 Filter.
• Check HEPA Filter airflow and visually check Filter surface (do not touch) to determine when
needing replacement. Estimate 2-3 years depending on conditions.
Actual Size: 23 3/8" x 23 3/8" x 12" (H13) HEPA-Filter.
NOTE: Consider a used HEPA Filter "contaminated" and discard with care!
• Clean exterior paneling / wheels using mild soap and a clean cloth.
• Visually inspect the unit, wheels, paneling, air-inlet grille and air-exit louver for proper
functioning and fit.
HEPA TOWER Installation and Operation Manual, 03-15-2021