DuraVent Hepa Tower Kurulum ve Kullanım Kılavuzu - Sayfa 7

Su Filtrasyon Sistemleri DuraVent Hepa Tower için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Kılavuzu indirin. DuraVent Hepa Tower 12 sayfaları.

DuraVent Hepa Tower Kurulum ve Kullanım Kılavuzu
HEPA TOWER SPECIFICATIONS
Dimensions:
77 3/8" High x 27" Wide x 20 3/8" Deep
Weight:
172 lbs
Electrical:
120VAC, 60 Hz, Single Phase, 2.5A
Tested Airflow:
62 / 940 CFM (Low / High)
Tested Power:
10 / 272 Watts (Low / High)
Tested Noise*:
42 / 59 dBa (Low / High)
Controls:
Low Voltage, Digital Touch Controller, Optional Wireless Remote.
Speed Settings:
10
Timer:
12 Hours, in increments of 1 Hour.
Warranty:
3 years mechanical & structural parts, 1 year control parts.
* Tested at 45° and 1 meter from source

MAINTENANCE

• Replace The Tower's Pre-Filter every 2-3 Months.
Actual Size: 23 3/8" x 23 3/8" x 1 3/4" (or 3/4") MERV11 Filter.
• Check HEPA Filter airflow and visually check Filter surface (do not touch) to determine when
needing replacement. Estimate 2-3 years depending on conditions.
Actual Size: 23 3/8" x 23 3/8" x 12" (H13) HEPA-Filter.
NOTE: Consider a used HEPA Filter "contaminated" and discard with care!
• Clean exterior paneling / wheels using mild soap and a clean cloth.
• Visually inspect the unit, wheels, paneling, air-inlet grille and air-exit louver for proper
functioning and fit.
HEPA TOWER Installation and Operation Manual, 03-15-2021
DuraVent ®, Inc., 2021. All Rights Reserved.
Page 7