apleton GEA 65-203601 Skrócona instrukcja obsługi
Przeglądaj online lub pobierz pdf Skrócona instrukcja obsługi dla Oświetlenie zewnętrzne apleton GEA 65-203601. apleton GEA 65-203601 2 stron. Exterior & garden lighting
Please read this manual carefully before installation. Installation, mounting or works on the electrical
connection may only carried out by an approved electrician.
Technical data:
Rated voltage: 220V~240V, 50Hz
Lamp: 220V~240V, GU10, 35W max
Installation instruction:
First check if the luminaire was damaged during the transportation. Ensure that the supply is switched off
before installation.
These unit are suitable for connection to a 220V~240V POWER supply.
•
Allow a minimum of 30cm gravel drainage under the body of the lamp. Test the drainage by
•
filling the tube with water.
The top of the mains sleeve should be mounted flush to the surface (pic.2) and then concreted.
•
Do not attempt to install during inclement weather conditions.
Insert the mains ( use only silicone cable, type H05SS-F, temperature resistant 180°C) into the
•
cable gland.
Connect the cable to the terminal block on the unit as following:
•
NEUTRAL
N
EARTH
LIVE
L
and fit the lamp into the housing. Secure tightly the cable gland nut (max 4Nm). Never cover the
visible part of the fitting with soil.
For the installation of 2-3 fittings it is possible to connect them like picture 4.
•
For installation of 4 fittings or more connect them like picture 5.
•
Screw the housing to the sleeve. Lay the diffuser. Overlap the stainless steel ring and screw
•
tightly.
Exterior & Garden Lighting
gea 65-203601