ASSEMBLY – INSTALLATION PIPES (continued)
Apply exterior finishes and waterproofing with
ROFLEX/TESCON tape combination or other
construction type specific measures.
ASSEMBLY - ELECTRIC INSTALLATION AND ELECTRIC CONNECTION
Safety Instructions: Beware! Any assembly work to the ventilation device may only be carried
out when all of the supply current has been disconnected! Make sure that all electrical circuits are
turned off. All controllers of this ventilation system should be installed on a AFCI protected circuit.
⚠
Electric connection only by a licensed electrician.
Questions? Email: [email protected] | Call: 800-995-6329
Remove the construction protection lid outdoors. Insert
and attach the exterior grill using the integrated claw
fasteners (tighten screws). Make sure the exterior grill
mounted with the louvers directing rain away from the
tube. Exterior grill finishes are also available in:
stainless steel, grey, burgundy, and white.
4
●
The system is controlled by
Universal Control 5/UNI-FR.
●
Select the location for the switch.
●
Run the wiring (120V + 12V cables
to the device pairs).
●
120V cable (14 gauge).
●
12V to each fan (3 x 18 gauge solid
thermostat wire).
●
Controller is wired and set per
diagram on following page.
4