Datacom Systems FTP-4000 Series Podręcznik szybkiego uruchamiania - Strona 2
Przeglądaj online lub pobierz pdf Podręcznik szybkiego uruchamiania dla Sprzęt sieciowy Datacom Systems FTP-4000 Series. Datacom Systems FTP-4000 Series 2 stron.
Tap Series FTP-1000,2000,4000
FASTstart Guide
Correct Wiring: When installing a Fiber Tap, it is important to make sure that the Tx and
Rx fibers are connected to the respective ports on the Fiber Tap. When wired correctly, the
traffic incoming on an Rx port will be split before being sent to two separate Tx ports (One
copy to the other Network device, the other copy to Monitor).
Reverse Wiring: If the fibers are connected backwards, light will not be received on the
monitoring port. This is because the internal coupler that splits the light is unidirectional.
To Avoid Reverse Wiring: Reverse wiring can be difficult to catch initially, since an
incorrectly cabled Fiber Tap will still send light between the network ports and connectivity
will be seen on both network endpoints. Be sure to check the for light on the monitor ports as
well as the network ports when installing the Fiber Tap.
Customer Service
is available from our website: www.datacomsystems.com or by calling +1 315 463 9541
© 2015 Datacom Systems, Inc
541-0149-R
For More information
Page 2
DATACOM
S Y S T E M S I N C