Motors with a power input exceeding 400 watt must be operated through a relay or
contactor with its own power supply.
Elsner Elektronik offers appropriate power supplies for direct current drives. Where re-
quired, please enquire indicating the motor types, the manufacturer and – if available
– the technical specifications.
Guide the power cable and the connecting cable for the drive through the rubber seal
on the lower side of the weather station. Connect the mains (L1/N/PE) and drive (PE/N/
up/down) to the appropriate terminals.
The teaching of wireless users at the weather station is easier if the weather station and
wireless actuators/sensors are secured via separate automatic circuit breakers.
Information on teaching wireless connections
To teach a wireless connection to the display observe the chapter creating wireless
connections in the manual (basic settings).
The wireless connection to the weather station can be created in two different ways:
1. By pressing the programming button.
This method may only be performed by a qualified electrician (according to VDE
0100) since the programming button for the wireless connection is on the weather
station circuit board.
2. By switching the power supply voltage off and on.
To enable this method, the weather station should be fused separately (16A circuit
breaker). Further wireless users can be supplied via other circuit breakers. Thereby
the power supply for the weather station and other wireless users can be interrupt-
ed independent of each other.