Installation Procedure
Prepare Installation Space
Create the cut-out in the countertop for one or several
Vario appliances according to the installation diagram.
The angle of of the cut surface to the countertop must
be 90°.
After creating cut-out, remove shavings. Seal cut
surfaces in a heat-resistant manner.
Some solid surface countertops require special
installations. For example, heat reflective tape and
rounded corners may be necessary. Contact the
countertop manufacturer for instructions specific to
your countertop.
Observe minimum distance between appliance
underside and furniture parts of
When installing multiple Vario appliances:
account space requirement for VV 200 connection
strip between the appliances. Appliances can also be
installed in individual cut-outs, bearing in mind a
minimum distance between the appliances of 1
(40 mm).
3
/
" (10 mm).
8
Take into
9
/
"
16
Install Appliance
,
WARNING:
Before you plug in an electrical cord
or turn on power supply, make sure all controls
are in the OFF position.
Make a mark exactly in the center of the cut-out.
1
Fasten the mounting rails to the front and rear
edge of the cut-out. The leading edges of the
mounting rails must lie upon the countertop. The
center marking of the mounting rails must
correspond precisely with the center marking of
the cut-out.
For stone countertops, adhere the
Note:
mounting rails with temperature-resistant duel-
component adhesive (metal on stone).
For combination with the VD 201 appliance cover:
2
Mount appliance cover to appliance prior to
installation (see VD 201 Installation Instructions).
Insert appliance in cut-out. The snap-in pins on
3
the appliance must lie precisely on the clamp
springs. Press appliance firmly into the cut-out.
The snap-in pins on the appliance must snap
into the clamp springs.
5