CEL-MAR ADA-4010A Podręcznik użytkownika - Strona 11

Przeglądaj online lub pobierz pdf Podręcznik użytkownika dla Konwerter mediów CEL-MAR ADA-4010A. CEL-MAR ADA-4010A 13 stron. Rs-485/rs-422 to rs-232 addressable converter
Również dla CEL-MAR ADA-4010A: Podręcznik użytkownika (16 strony)

CEL-MAR ADA-4010A Podręcznik użytkownika
ADA-4010A

APPENDIX A. TERMINAL DESCRIPTION OF RS232 INTERFACE.

Terminal
TX
RX
RTS
CTS
DSR
DTR
GND

APPENDIX B. SPECIFICATION

Connector
Line length
Max. number of connected device
Transmission line
Standards
Transmission type
Optical Signalization
Power requirements
Power Cable
Power
Protection from reverse power polarization
Galvanic Isolation
Optoisolation
Operating temperature
Humidity
Location during work
Mounting
Electromagnetic compatibility
Safety requiring
Environment
Dimensions
Material
Degree of casing protection
Degree of terminal protection
Weight
According to standards
Storage temperature
Humidity
Signal
Description
(TD)
Transmitted Data
(RD)
Received Data
(RTS)
Request To Send
(CTS)
Clear To Send
(DSR)
Data Set Ready
(DTR)
Data Terminal Ready
(SG)
Signal ground
Transition Parameters
Screw terminal block - max. Ø 2,5mm
Multiwire cable 9x0,34 in shield
EIA-232, CCITT V.24,
Asynchronous full duplex, half duplex.
• PWD – green LED power supply,
• RX - red LED data receiving on RS-232 side,
• TX - yellow LED data transmission via RS-232 inteface.
Nominal Operating Conditions
Recommended length of power cable – up to 3m
1kV= or 3kV= DC between power circuit and RS-485/422 signal line
5kV= between signal line RS485/422 and RS-232
Free.
Rail mounting according to DIN35 standard / TS35.
Resistance to disruptions according to the standard PN-EN 55024.
Emission of disruptions according to the standard PN-EN 55022.
According to the PN-EN60950 norm.
Commercial and light industrial.
Storing and Transportation
ADA-4010A
Transmitter
Receiver
Looped with CTS
Looped with RTS
Looped with DTR
Looped with DSR
GND
RS-232
2
up to 15 m
1
10 - 24 – 30 V DC
<2W
YES
0 ÷ +23 ÷ +50°C
5 ÷ 95% - non-condensing
Casing
53 x 90 x 58 mm
Noryl UL. 94 V-O
IP40
IP20
0,10 kg
DIN EN50022, DIN EN43880
-40 ÷ +70°C
5 ÷ 95% - non-condensing
11
RS-485/RS-422
Screw terminal block - max. Ø 2,5mm
1200 m
32
1-pair or 2-pair twisted cable, UTP
Nx2x0,5 (24AWG), shield inside large
interferences STP Nx2x0,5 (24AWG)
EIA-485, CCITT V.11
2