If you set configuration mode an yellow LED located beside SW1 micro-switch will blink with frequency 1 Hz. Press a button
[Load New Firmware] to change the software delivered by manufacturer. The Select File window will open (Fig.8) and select the *.bin
file then click [Open] - software will be load to ADAConfig buffer storage and checked. If ADAConfig does not detect errors in loaded
file you can change converter software. Process of software changing is visualized by ADAConfig in use Progress Window and after
proper changing confirmed by correct message.
During loading software an yellow LED located by SW1 micro-switch will blinks, showing data flow to converter. If the Software loaded
correctly yellow LED will be blink with frequency 1 Hz.
Return to normal operating mode is made by using SW1 switch (yellow LED blink OFF) as below.
SW1-1
SW1-2
OFF
OFF

5.4. EMERGENCY SOFTWARE UPDATING

In a case of the unsuccessful updating of the converter software, try again according to description in item 5.2. If the exchange is still
incorrect use emergency software changing. You can entered in this mode by using SW1 micro-switch as below:
SW1-1
SW1-2
ON
ON
After micro-switch setting you should restart the converter by turning OFF and then ON ADA-4010A power supply. If the yellow LED is
light continuously the converter will be in emergency software updating mode. Now you have to follow on the description in item 5.2 .
AFTER SUCCESSFUL RELOAD OF PROGRAM MICRO SECTION OF SW1 SWITCH SHOULD BE SET LIKE IN TABLE BELOW
SW1-1
SW1-2
OFF
OFF

6. DATA TRANSMISSIONS DIAGNOSTIC

To readout diagnostics you should set SW1 to configuration mode (see paragraph 5.1).
Correctness of transmission proceed on RS232 and RS485/422 interfaces you can check by readout error list by use ADAConfig
Software form the converter memory. Frames error meter will be increased for example: in case of improper speed set compared to
real speed of data transmission. Parity error meter will be counted errors which can arise in case of misrepresent bytes in transmitted
sign. This meter will not work in case of disable control parity. If you want to check this meters press the button [Read transmission
errors], and to delete (zeroing of meters in the memory of the converter) press [Delete transmission errors].
In case of parity errors or frame errors you should check ADA-4010A converter's configuration and connection correctness of
– RS485 network connection to RS485/RS422 port,
– addressable device to converter's RS232 port.
When you will finish diagnostic you should set SW1 micro-switch to normal mode (see paragraph 5.1)

7. OPERATES DESCRIPTION

ADA-4010A converter can operate in addressable mode and not addressable mode.

7.1. OPERATING IN NOT ADDRESSABLE MODE

ADA-4010A operates as baud rate and data format converters in not addressable mode and let you to set different baud rates and
data formats on RS232 and RS485/422 interfaces.
This allows you to connect old devices operates with not configure baud rate and data format on RS485 Bus, where operate devices
with different baud rate or different data format.
Fig 8. Selection of firmware file
ATTENTION!!!