HIBLOW hp-120 Instrukcja obsługi - Strona 8

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Sprężarka powietrza HIBLOW hp-120. HIBLOW hp-120 13 stron.
Również dla HIBLOW hp-120: Podręcznik (9 strony)

HIBLOW hp-120 Instrukcja obsługi
Fig. 4
Screwdriver
inserting
position
Frame cover
Replacing Diaphragm mounting block
After removing Head (Casing) block, remove one of the hex nut (U-lock nut) and washer in the
center of the diaphragm.
Remove one of the Diaphragm mounting blocks from the Rod, and pull out the other Diaphragm
mounting block from the pump body together with the Rod without loosening its hex nut (U-lock
nut) and washer. (Refer to Fig.5- )
Then remove the other Diaphragm mounting block from the Rod. (Refer to Fig.5- )
Reattach a new Diaphragm mounting block on one side of the Rod with new hex nut (U-lock nut)
and washer, insert the Rod in accordance with the procedure reverse to that performed when the
Rod was removed the pump.
Reattach washer and new hex nut (U-lock nut) to Rod screw protruding through other Diaphragm
mounting block and tighten.
Fig. 5
Screw
Sound absorber
Screw
(Refer to Fig.5)
Diaphragm
mounting block
Diaphragm mounting block
Upper housing
Screw
Hose band
L-tube
Screw
Head (Casing) B
Washer
U-lock nut
L-tube
Head (Casing) block
Head (Casing) A
Valve chamber packing
Rod