Automation Dr. Nix QNix 5500 Instrukcja obsługi - Strona 11

Przeglądaj online lub pobierz pdf Instrukcja obsługi dla Przyrządy pomiarowe Automation Dr. Nix QNix 5500. Automation Dr. Nix QNix 5500 20 stron.
Również dla Automation Dr. Nix QNix 5500: Skrócona instrukcja obsługi (12 strony), Instrukcja obsługi (16 strony)

Automation Dr. Nix QNix 5500 Instrukcja obsługi
5500
7 Appendix
7.1 Gauge Technical Data
7.1.1 Gauge Mechanical Data
Mechanical Data
Display
IPS-LCD, 2", colour, 600 lm,
viewing angle 70° in all directions
Dimensions (L x W x H)
Approx. 160 mm x 68 mm x 38 mm
Weight (without batteries)
Approx. 270 g
Robustness / ambient conditions
IP rating
IP65
Operating temperature
-20 °C to +70 °C
Storage temperature
-20 °C to +70 °C
7.1.2 Gauge Electrical Data
Electrical data
Protection rating
III
Device power supply
2 x batteries 1,5 V (type AA)
Battery life without operation at min.
> 1 year
50% battery capacity
Battery life at one measurement per
min. 60 000 measurements
second
7.2 Probe Technical Data
7.2.1 Probe mechanical data
Mechanical Data
Upper housing material
Stainless steel (1.4305)
Bottom housing material
Trogamid® (CX7323)
Test prod material
polished ruby (Al203)
Dimensions (length / diameter)
35.5 mm / 14.5 mm
Weight
11.9 g
20
20 / 31
7 Appendix
QNix 5500 EN_ES_FR_IT_NL_PL
7 Appendix
Robustness / ambient conditions
IP rating
IP65 (closed)
Operating temperature
-20 °C to +70 °C
Storage temperature
-20 °C to +70 °C
Max. surface temperature in
80 °C
continuous measurement mode
Max. surface temperature at 1s test
100° C
time ever 20s
7.2.2 Probe Electrical Data
The probes may only be used with the gauges QNix® 9500 and QNix®5500.
7.3 Measuring Data
Measuring Data
Fe
Principle of Measurement
Magnetic field principal
Magnetic field change,
Hall effect
As per standard (varies by model)
DIN EN ISO 2808,
DIN EN ISO 2178
DIN 50981, DIN 50984, BS 5411 (3 & 11), BS 3900-C5,
ASTM B 499, ASTM D 1400, ASTM D 1186, ASTM D 7091
Status indication
By RGB-LED at the probe
Probe type
See probe data sheet
Measuring range
Varies by probe type
Measuring interval
>= 100 measurements / min
Units
µm / mil (setting in battery compartment)
Display resolution
0.1 µm
Measurement uncertainty*
± (1 µm + 2 %) up to 2 mm
(based on factory standards)
± 3 % from 2 mm
Minimum measuring area (Ø)
14.5 mm
Minimum curvature radius, convex
6 mm
Minimum thickness of the
100 µm
base material
* Accuracy may deviate outside a range of -5 °C to 65 °C, but not more than the factor 2 of the
measurement uncertainty.
QNix 5500 EN_ES_FR_IT_NL_PL
5500
NFe
Magnetic field principal
Eddy current
DIN EN ISO 2808,
DIN EN ISO 2360
± (2 µm + 2 %) up to 2 mm
± 3 % from 2 mm
14.5 mm
50 mm
50 µm
21 / 31