Autopage MA-200 Instrukcja instalacji - Strona 7
Przeglądaj online lub pobierz pdf Instrukcja instalacji dla System bezpieczeństwa Autopage MA-200. Autopage MA-200 8 stron. 2-way remote control motorcycle alarm
Również dla Autopage MA-200: Instrukcja obsługi (13 strony)
30/ 60/ 90seconds timed output = A 30, 60, or 90-second timed output will send a signal for 30, 60, or 90
seconds, respectively, when the channel 3 / 4 transmitter button(s) are pressed.
III
ALARM FEATURE "
" PRORAMMING:
1. Turn the Ignition 'switch 'ON/OFF' 3 TIMES and stay in OFF position.
2. Push the Valet switch 6 times and hold in on the 6
then release the valet switch. You are now in the Alarm feature 'III' programming mode.
3. Press and release the transmitter button 'A' corresponding to the feature 'A' you want to program.
Press
One Chirp /
T
r
LED one pulse
ransmitte
Button
Factory Default Setting
Exit the programming mode. (3 long chirp to confirm this exit.)
1
Override Without Password Pin Code
2
( Press & hold
delete the Password pin code)
F
Adjust and Test the sensitivity level of the
3
Shock Sensor. (Press & hold
2 seconds)
Exit:
Turn the Ignition to the 'ON' position, or leave it for 15 seconds. 3 long chirps will confirm exit.
Password Pin Code Setup:
1. Turn the Ignition 'switch 'ON/OFF' 3 times and stay in OFF position.
2. Push the Valet switch 6 times and hold in on the 6
then release the valet switch. You are now in the Alarm feature 'III' programming mode.
3. Press and release
button on the transmitter once, [2] LED flash, [2] siren/horn chirp to indicate you
are in features "Password Pin Code Programming mode".
4. Within 15 seconds, begin to enter your selected number by pressing and releasing the valet Switch from
1 – 9 times.
5. Finish by turning the ignition switch to the "ON" position.
If the new password code was accepted, the unit would report back the newly entered code, by flashing
the LED, first indicating the first digit code has been memorized. The unit will report the new code three
times with a one-second pause between each code.
Note: If 15 seconds of inactivity expire, or
unit will revert back to the last successfully stored code. 3 long chirps will confirm exit. The unit will revert
back to the last successfully stored code
Delete Password Pin Code / Override Without Password Pin Code (Factory default setting):
1. Turn the Ignition 'switch 'ON/OFF' 3 times and stay in OFF position.
2. Push the Valet switch 6 times and hold in on the 6
then release the valet switch. You are now in the Alarm feature 'III' programming mode.
3. Within 15 seconds, press and hold
Deleting the Password Pin Code.
Adjust and Test the sensitivity level of the Shock Sensor
1. Turn the Ignition 'switch 'ON/OFF' 3 TIMES and stay in OFF position.
2. Push the Valet switch 6 times and hold in on the 6
then release the valet switch. You are now in the Alarm feature 'III' programming mode.
F
3. Press and hold the
button on the transmitter for 2 seconds. 2 Chirp will indicate the unit is ready to
accept adjustments of the "Full-Alarm" sensitivity.
F
4. Pressing the
button on the transmitter once will decrease the sensitivity level by one, each time a
decrease is made the siren/horn chirp will respond number of chirp which indicates level of
sensitivity.
5. Pressing the
button on the transmitter once will increase sensitivity level by one, each time an
increase is made the siren/horn chirp will respond number of chirp which indicates level of
sensitivity.
MA200 IN REV.A
th
push until three chirps with a long chirp is heard
Two Chirps /
LED two pulses
Override With Password Pin Code
(Password pin code programming)
button for 4 seconds to
F
button for
th
push until three chirps with a long chirp is heard
button on the transmitter is press during of above steps, the
th
push until three chirps with a long chirp is heard
button on the transmitter for 4 seconds. One chirps to confirms
th
push until three chirps with a long chirp is heard
7