INSTALLATION INSTRUCTIONS

This fireplace unit must be installed by a qualified, competent installer.
A. Location
1.
The fireplace unit must not be in contact with any combustible
materials.
2.
The heater, which is located at the base of the appliance, must kept
clear of obstruction and must be a minimum of 15 inches away from
any combustible material.
3.
It is important that the wall on to which the fireplace unit is to be
installed is of sound construction. All fixings must be suitable for
the type of wall, must be secure to the wall and capable of taking the
weight of the fireplace unit.
4.
The fireplace unit must not be installed in an area where there is
restricted air flow around the fireplace unit.
5.
This fireplace is approved for indoor installation (include bathroom)
and is approved for some outdoor installation. The fireplace must be
kept away from any source of damp or moist conditions. Avoid any
close contact with water. For outdoor installation, the fireplace unit
must be located in fully covered areas.
6.
If there is any doubt regarding the suitability of the installation site
contact your supplier.