INSTRUCTIONS: IN-6000
Cod: DYN 27.04
Date: 20/10/2020
Revision: 04
3 INSTALLATION AND ADJUSTMENT
3.1 ASSEMBLY ON THE FRAME
The holes should be made on the frame's uprights to secure the safety gear, according to the dimensions
and position displayed in the safety gear drawings attached, ensuring that the guide rail's axis is centred with
the frame.
To secure the safety gear onto the frame, we recommend a 79.09 Nm tightening torque for grade 8.8 M12
bolts, and of 111 Nm for grade 10.9 bolts.
Figure 2 Assembling the safety gear onto the frame
⚠
a)
Safety gear position: The safety gears should be assembled in the position displayed in Figure 3
Figure 3: Direction of assembly
During assembly, the safety gear should be perfectly aligned with the guide rails, both vertically and
horizontally. Improper assembly may cause the safety gear to function incorrectly.
Note: This manual displays partial information on the instructions for use and maintenance of this product. Please refer to the
3
customer area in Dynatech's website in order to consult the full manual; http://customers.dynatech-elevation.com/