Galvin Specialised Flowmatic TZ-FLOW225866 Instrukcja instalacji produktu - Strona 5

Przeglądaj online lub pobierz pdf Instrukcja instalacji produktu dla Akcesoria Galvin Specialised Flowmatic TZ-FLOW225866. Galvin Specialised Flowmatic TZ-FLOW225866 10 stron. Wall mounted sensor tap battery operated/single temp

Galvin Specialised Flowmatic TZ-FLOW225866 Instrukcja instalacji produktu
SETTINGS ADJUSTMENT
DETECTION RANGE: Only if necessary, use the remote control to adjust the sensor range as
follows:
Press the RANGE button. Wait until a quick flashing of the LED in the sensor eye is
perceived. Then, press + to increase the one level and – to reduce it every push will
increase or decrease one level.
NOTE: Once you have changed the detection range with the remote control, this distance will be remembered by
DELAY IN TIME: This button allows modifying the flushing start time after the user is within the
product's sensor range. The delay in time can also be modified as follows:
Press the IN button. Wait until a quick flashing of the LED in the sensor eye is perceived.
Then, press + to increase the delay in time and – to reduce it.
DELAY OUT TIME: This button allows modifying the flushing stop time after the user moves
away from the sensor range. A delay out time close to 0 will save more water. An increased
delay out time will make the user experience more comfortable.
If required, the delay out time can be modified as follows:
Press the OUT button. Wait until a quick flashing of the LED in the sensor eye is
perceived. Then, press + to increase the delay out time and – to reduce it.
TEMPORARY OFF FUNCTION: This function is ideal to perform any kind of activity in front of
the sensor without operating the system (for example, cleaning).
The product will remain shut for 1 minute when this button is pressed once. To cancel this
function and to return to normal operation press the On/Off button again or wait 1 minute.
RESET BUTTON: This function restores all the factory settings except for the sensor range. If
required, press the Reset button and without releasing it, press the + button once.
SECURITY TIME: The Security time, prevents continuous flushing of water due to reflections
or vandalism. By default, if the sensor is covered for more than 90 seconds the water flow will
shut automatically. To resume regular operation any obstruction must be removed.
Press the SEC button. Wait until a quick flashing of the LED of the sensor eye is
perceived. Then, press + to increase the security time and – to reduce it.
24 HOUR HYGIENE FLUSH: This model includes a 24 hour hygiene flush which is disabled.
To activate the hygiene flush, press the clock button. Wait until a quick flashing of the LED in
the sensor eye is perceived. Then press + to activate the hygiene flush. To disable it again,
press – to deactivate it.
COMFORT FLUSH: If your model includes a COMFORT FLUSH setting, it can be activated by
pressing the flush button. When the button is pressed, one blink of the blue in the sensor eye is
perceived. The pre-programmed flush cycle will take place then. The Comfort flush cannot be
interrupted or deactivated by pressing any button until it is over.
the sensor, even if the power source is disconnected.
th
Version 2, 16