Afore HNS3000TL Podręcznik użytkownika Instalacja - Strona 12
Przeglądaj online lub pobierz pdf Podręcznik użytkownika Instalacja dla Falownik Afore HNS3000TL. Afore HNS3000TL 17 stron. Pv inverter single mppt
5.3.1 Conditions for the DC Connection
• The connected PV modules must meet the following requirements
– Same type
– Same number
– Identical alignment
– Identical tilt
• The following limit values at the DC input of the inverter must not be exceeded
(connecting to a higher voltage will destroy the device):
Anyhome
Maximum input voltage Maximum input current
HNS3000TL 550V
5.3.2 Assembling the DC Plug Connector
In order to connect to the inverter, all connection cables of the PV modules must be
equipped with the DC plug connectors provided. You will find the necessary DC plug
connector for DC connection in the delivery.
To assemble the DC plug connectors, proceed as detailed below. Ensure the plug
connectors have the correct polarity. The whole connector will include the male side
and female side as showed below.
Male side connector(M)
Female side connector(F)
Assembly Instructions:
Adjust the striper stopper and put the cable in corresponding notch to strip the
1.
length of 12mm. Please refer to the following figures.
17.5A