4.2.2 Bar Shower Body (See Fig. 1b)
To fit mixer body to the wall. Place the filter washers (6) into the connecting nuts (7)
and tighten to the fixing bridge (4 on page 3. Fig. 1a) using the connecting nuts (7)
which are secured to the mixer body.
5.1 The maximum temperature (beyond the 38°C click) can be adjusted to suit site
conditions or user preference. To adjust this, follow this procedure:
5.2 Position the temperature control handle to click stop point and turn on the flow
handle control handle letting the water run long enough to ensure that the hot water
supply is at its maximum temperature.
5.3 The shower has been factory set to 38
pressures of 0.5 Bar.
5.4 Whilst the water is flowing remove the temperature control handle (10) and shroud
(12), by pulling the handle off the spline adaptor (11).
5.5 Turn the spline adaptor (11) until the required maximum temperature is achieved
(the spline adaptor many need to be reposition to allow the head to line backup with
the body of the shower), anti-clockwise to increase the temperature and clockwise to
reduce it.
5.6 Important: Refit the shroud and handle and shroud so that the stop pin in the handle
(10) fits inside the rim of the white nylon stop ring (15).
5.7 Push the shroud (12) and handle back on and turn clockwise. The handle should
click. This is quite normal.
5.8 Turn off the flow at the flow control handle.
6.1 On / Off - Flow Control
There are two control handles on the shower. Turn the flow control handle (left)
anti-clockwise to turn on and increase the flow, and clockwise to decrease and turn off.
The temperature control handle (right) is turned anti-clockwise for hot, clockwise for
cold and features a 'temperature click notch'. The 'click' is factory set to 38
over ridden by turning the handle anticlockwise past the click stop position.
For latest prices and delivery to your door visit MyTub Ltd 0845 303 8383 www.mytub.co.uk
5. Setting
o
C at the click position with balanced supply
6. Operation
6
o
C, but can be