Operation
On
Off
Off
On
Hot
Maintenance - Valve Cleaning
1
IMPORTANT
Isolate the
water supply
before
starting!
Prise off the caps
and indices.
Undo the screws to
remove the handles.
3
Place valves
in a suitable
solution and
soak until
fully de-scaled.
General Cleaning
Bristan products are made from premium
materials, with hand polishing and
electroplated finishes.
Your taps or shower should be regularly
cleaned with warm water, a mild pH-neutral
liquid soap, and polished with a soft cloth.
Cold
Any residues from soap, toothpaste,
shampoos and shower gels can cause
blemishes if not rinsed off straight after use.
Household bleaches and cleaners contain
harsh chemicals and may damage the surface
finish. Avoid using abrasive cloths, scouring
pads, scrub sponges, steel wool
or anything similar.
Some surfaces such as nickel and pewter
may be affected by the dye found in some
cloths, so it is also important to avoid
hanging cloths on spouts.
2
Unscrew the valve
using an adjustable
spanner.
Check any seals
and O-rings for
damage. Replace
valve if necessary.
4
Reverse the steps to replace the
valves and handles.
Maintenance - Clean/Replace Outlet
1
2
IMPORTANT
Soak using a suitable
Isolate the
water supply
before
starting!
Using long-
nosed pliers,
unscrew
gently to
remove the
outlet.
Screw back into the tap
body to replace the outlet.
Troubleshooting
Symptom
Cause
Partially closed isolation valve.
Instantaneous water heater cycles on
and off as flow rate or pressure is too
low.
Head of water is below the
No flow or
minimum distance required.
low flow
Hot or cold water being drawn off
rate
elsewhere causing pressure changes or
instantaneous boiler temperature
changes.
Airlock or partial blockage in the supply
pipework.
This is normal for a short time after using
Water
the taps.
dripping
If water continues to drip,
from taps
possibly due to the ceramic disc valves
Closed isolation valve.
Taps do not
turn on
Mains water supply turned off.
Love Your Chrome
At Bristan, we want to make things as easy as possible for our customers.
That's why we offer solid guarantees on all our products, effective from the date of purchase,
to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register to register your product via a computer.
For full guarantee terms and conditions visit www.bristan.com/guarantees.
Notes
Please use this space for any notes
Check for damage.
you or your installer may have
regarding the installation/plumbing
solution to de-scale.
of this product.
Remedy
Open isolation valve.
Increase water flow rate or pressure through system.
Refer to specification for minimum distance required.
Do not use other water outlets when using the taps.
Flush through pipework to ensure removal of debris
and any airlocks.
This is caused by residual water tension, the build up
of water in the tap body.
Remove valves and clean, refer to 'Maintenance'
section before starting any maintenance.
Open isolation valve.
Turn on mains water supply.
Bristan offers an effective chrome-friendly cleaning kit
for use with your taps and showers. Scan the QR Code