4. Specifications
4.1. Specifications
Function
AC Current
Over range protection: Maximum input 200A.
Frequency Response: 50 to 60Hz
Function
AC True RMS Voltage
(Auto Ranging)
Input Impedance: 10MΩ; Low Input Impedance Test Voltage: ±3kΩ MAX 600V AC
Accuracy Specified from +3.0% of rdg +8 digits;
Over Range Protection: 1000V RMS; Frequency Response: 50 to 1000Hz (sine wave),
50/50(All wave)
Function
DC Voltage
(Auto Ranging)
Input Impedance: 10MΩ; Low Input Impedance Test Voltage: ±3kΩ MAX 600V AC
Accuracy Specified from +3.0% of rdg +8 digits;
Over Range Protection: 1000V
Function
Resistance
Over Range Protection: 300V RMS
Function
Capacitance
*>6nF no specification; Over Range Protection: 300V RMS
8
Range
Resolution
100mA
200.0A
Range
Resolution
6.000V
1mV
60.00V
10mV
600.0V
100mV
1000V
1V
Range
Resolution
6.000V
1mV
60.00V
10mV
600.0V
100mV
1000V
1V
Range
Resolution
600.0Ω
0.1Ω
1Ω
6.000kΩ
10Ω
60.00kΩ
100Ω
600.0kΩ
1kΩ
6.000MΩ
10kΩ
60.00MΩ
Range
Resolution
60.00nF
0.01nF
0.1nF
600.0nF
1nF
6.000µF
0.01µF
60.00µF
0.1µF
600.0µF
1µF
4000µF
Accuracy ±(% of reading+digits)
±(3% + 5 digits)
Accuracy ±(% of reading+digits)
±(1.2% + 5 digits)
±(1.2% + 2 digits)
±(1.5% + 2 digits)
Accuracy ±(% of reading+digits)
±(0.9% + 5 digits)
±(1.0% + 2 digits)
±(1.2% + 2 digits)
Accuracy ±(% of reading+digits)
±(1% + 4 digits)
±(1.5% + 4 digits)
±(2.5% + 4 digits)
±(3.5% + 4 digits)
Accuracy ±(% of reading+digits)
±(3% + 5 digits)
±(3.5% + 10 digits)
±(5.0% + 10 digits)