Complete Preparation
1. Determine and make all necessary cuts in the wall for the vent
system. Install the vent system before installing the hood. See
"Venting Requirements"
section.
2. Determine the required height for the home power supply
cable and drill a 11¼"(3.2 cm) hole at this location.
3. Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough 1/2"conduit and wires from
the fused disconnect
(or circuit breaker) box to make the
connection in the hood's electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4. Use caulk to seal all openings.
1.
Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
A
For non-vented (recirculating) installation only:
1. Assemble the air deflector with the two extensions with
2 - 3.5 x 6.5 mm screws provided.
A
,%
A
2.
A. 3.5 x 6.5 mm screws
Assemble the air deflector with the duct cover bracket with
4 - 3.5 x 6.5 mm screws provided.
C
A. Mounting screws
B. Mounting slots
C. Lower mounting screws with flat washers
2. Remove the grease filter. See "Range Hood Care" section.
3. Level the range hood and tighten upper mounting screws.
4. Install 2 - 5 x 45 mm lower mounting screws with flat washers
and tighten.
1.
3.
Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
A. Vent cover bracket
B. 3.5 x 6.5 mm screws
C. Air deflector
Measure from the bottom of the air deflector to the bottom of
the hood outlet.
.........................................
A
g
...................
DE
i!._1
x ...............
C
A. Vent transition
B. 3.5 x 9.5 mm screw
For vented installations only:
1. Fit vent system over transition piece.
2. Seal connection with clamps.
3. Check that back draft dampers work properly.
A. Air deflector
B. Vent clamp
C. X = length to cut vent duct
D. Vent duct
E. Exhaust outlet
4. Cut the duct to the measured size (X).
5. Remove the air deflector.
6. Slide the duct onto the bottom of the air deflector.