Console has no power, no display:
Is this a machine that has just
been assembled and installed?
Yes
Check the console wires.
They should not be crushed,
pinched or cut. Refer to
photos at right.
3.2.
Loss of Key Function
Did all keys loose function?
Yes
Turn OFF the AC power.
Wait for 10 seconds then
turn ON the AC power. Are
the keys working properly?
Yes
Caused by external noise.
Need to determine source
and check again.
* The system will not allow the incline keys to function if the wires are not connected from the
incline motor to the motor controller.
www.GreenSeriesFitness.com
Open the motor cover,
check the D8 lamp.
No
Does it illuminate?
Yes
Open the console and
refer to page 6 and
measure the voltages
of Pin 11 and 12 of the
upper console. Does
it have 12V power?
Yes
Replace the
console PCB.
No
Open the console and refer to page 6 to
short circuit the pins of the console PCB
related to the non-functional key(s).
Does the key work with the pins shorted
without the membrane or switch?
No
For example, if the speed key did not
work, short circuit pins 2 and 5 of J2. If
the console is good, the speed should
change.
Replace the membrane key or
the switch PCB.
©May 2015
CIR-TM6000DC-G Revision 1.1
No
Motor controller faulty.
Replace the motor
controller.
No
Replace the
console wire.
Yes
Call Toll free (800) 269-7140
No
Replace the
console PCB.