Installation:
•
Ensure the installation location has dedicated power:
•
Countertop models can simply be placed on a flat, level surface. There might be at least 2" of clearance around the unit at all
times for proper ventilation.
To install drop-in models, follow the steps below:
Note: Countertop thickness must not exceed 2".
Note: Drop-in models should only be installed by professionals.
1.
Ensure the installation location has proper ventilation. There must be at least 7" of available space under the mounted induction
range and the inside temperature of the cabinet must not exceed 90F.
2. Drop-in models feature remote control. The control panel will be mounted separately for easy access.
3. Use and place the provided template in the intended installation location, allowing at least 4" of countertop space on each side.
Cut the countertop using the template and cutout dimensions illustrated in the manual.
4. Insert the induction range into the cutout and apply a thin layer of silicone sealant around the surface.
5. Repeat similar instructions for the control panel. Center the control panel to the induction range whenever possible.
6. Connect the control panel cable to the induction warmer.
Note: drop-in models can be daisy-chained.
Daisy Chain Setup:
All induction warmers feature a built-in power receptacle which allows for daisy-chain use with additional warmers. Connecting up
to five 16" x 16" warmers and three 16" x 23" warmers with the built-in power receptacle allows for daisy-chain use.
1.
Plug one warmer into a grounded electrical outlet with the matching serial plate rated voltage.
2. Plug the power cable of the additional warmer into the side of the warmer connected to the electrical outlet.
3. Do the same for additional warmers.
4. Maintain at least 2" clearance between connected warmers.
Note: The induction warmer connected to the electrical supply must remain turned on to supply power to other
connected units. Each unit is still controlled independently.